Яшил иқтисодиёт ва тараққиёт 3-jild 10-son (2025) · 79-91-betlar

DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION, CONSTANT-CURRENT ELECTRICAL MUSCLE STIMULATOR WITH INTEGRATED SAFETY FEATURES

Davronova, Dilora

Manbada oʻqish PDF

Annotatsiya

This study presents the development and experimental validation of a high-precision constant-current Electrical Muscle Stimulator (EMS) with integrated safety mechanisms for transcutaneous neurostimulation. To address the main drawback of traditional voltage-source designs—output current variation resulting from changes in skin-electrode impedance—an updated Howland pump configuration is used as a precision voltage-controlled current source (VCCS). The circuit incorporates precisely matched 100Ω resistors and a TLO72 operational amplifier, ensuring output current stability within ±5% for load impedances typical of human tissue (500Ω–2 kΩ). An NE555 timer configured as an astable multivibrator generates adjustable biphasic pulses with a frequency range of 1–6.35 Hz, encompassing the therapeutic bands commonly employed in rehabilitation and pain relief. A key aspect of the design is the incorporation of robust patient safety features—often absent from research-grade stimulators—such as galvanic isolation via a medical-grade output transformer and a series 10µF DC-blocking capacitor. Collectively, these provisions guarantee compliance with the IEC 60601-1 standard for medical electrical equipment. Tests demonstrate reliable delivery of a stable balanced biphasic output current across a range of load conditions. The prototype thus confirms that clinical performance in terms of accuracy and safety can be achieved with inexpensive components, offering a reliable and versatile platform for neuromuscular exploration and future electrotherapeutic applications.

Electrical Muscle StimulatorConstant-Current ControlRehabilitation DeviceNeuromuscular StimulationMuscle Activation

Metadata manbasi: jurnal OAI-PMH arxivi · Sindex toʻliq matnni saqlamaydi, manbaga havola beradi.

Iqtibos olish

APA 7
Davronova, Dilora (2025). DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION, CONSTANT-CURRENT ELECTRICAL MUSCLE STIMULATOR WITH INTEGRATED SAFETY FEATURES. Яшил иқтисодиёт ва тараққиёт, 3(10), 79-91.
GOST R 7.0.5
Davronova, Dilora DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION, CONSTANT-CURRENT ELECTRICAL MUSCLE STIMULATOR WITH INTEGRATED SAFETY FEATURES // Яшил иқтисодиёт ва тараққиёт. 2025. Т. 3. № 10. С. 79-91.
BibTeX
@article{dilora2025,
  author  = {Davronova, Dilora},
  title   = {DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION, CONSTANT-CURRENT ELECTRICAL MUSCLE STIMULATOR WITH INTEGRATED SAFETY FEATURES},
  journal = {Яшил иқтисодиёт ва тараққиёт},
  year    = {2025},
  volume  = {3},
  number  = {10},
  pages   = {79-91}
}
RIS
TY  - JOUR
AU  - Davronova, Dilora
TI  - DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION, CONSTANT-CURRENT ELECTRICAL MUSCLE STIMULATOR WITH INTEGRATED SAFETY FEATURES
JO  - Яшил иқтисодиёт ва тараққиёт
PY  - 2025
VL  - 3
IS  - 10
SP  - 79
EP  - 91
ER  -